What DEQX Calibrated™ does for listening rooms • Automated measurement and correction using calibrated mic
• DEQX minimum-phase 10-band parametric EQ
• Graphic view of room acoustic behaviour on PC during set-up
• WYSIWYG control of room correction curve, with pinpoint accuracy
• Manual override of parametric bands in graphic environment
• Listen to music and change individual band correction in real time
• Multiple measurements can be taken to help place speakers or evaluate room treatments |
 |
Once the speakers are managed using DEQX™ speaker correction, the in-room response is
measured and corrected. DEQX™ room correction is then targeted directly at the room acoustic
effects, rather than trying to correct everything in one go. Listening position measurements are taken using a calibrated microphone. The measurements
produce an impulse response and frequency response of the room, which can then be used for
analysis. The room correction can be tailored to each user's preference, allowing control of the
frequency correction region, maximum boost and cut, and different EQ styles. When using multiple
measurement positions, only common peaks and troughs present in each measurement are
corrected. Alternatively the user can sum together any set of measurements, or select one that
is characteristic of a group. DEQX™ cepstrum based logarithmic smoothing allows a controllable
amount of resolution in the measurement signal without destroying the phase response. This more
accurately represents the room response that we perceive. The flexible measurement analysis system allows objective acoustic evaluation of speaker and
subwoofer placement, and any physical room treatments or furniture placement. DEQX™ room
correction then allows the remaining room response modes (which were previously unmanageable
to be corrected. return to top |
|
 |
|
|
 |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
|